HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
Fabric OS 5.x diagnostics and system error messages reference guide 87
Viewing system messages from AdvancedWeb Tools
This procedure is valid for HP StorageWorks Fabric OS 5.x switches.
To view the system message log for a switch from Advanced Web Tools:
1. Launch Web Tools.
2. Select the desired switch from the Fabric Tree. The Switch View displays.
3. Click the Switch Events button. A Switch Events Report appears.
4. View the switch events and messages. In dual-domain switches, an Event button exists for each logical
switch. Only messages relating to that switch (and chassis) will be displayed.
Dumping the system messages
This procedure is valid for the HP StorageWorks Fabric OS 5.x swit ches.
To display the system message log, with no page breaks:
1. Log in to the switch as admin.
2. Enter the errDump command at the command line:
switchname Switch name or
chassis name,
depending on the
action; for example,
HA messages typically
show the chassis name
and login failures
show the logical
switch name.
This field displays the defined switch name
or the chassis name of the switch. This
value is truncated if it is over 16 characters
in length. Run either the chassisName
command to name the chassis or the
switchName command to rename the
logical switch.
Slot 7 ejector not
closed
Error Description This field displays a text string explaining
the error encountered and providing
parameters supplied by the software at
runtime.
Table 3 Error message field description (continued)
Example Variable Name Description
switch:admin> errDump
Version: 5.0.1
2004/07/28-17:04:59, [FSSM-1002], 1,, INFO, switch, HA State is in
sync
2004/07/28-17:04:59, [FSSM-1003], 2,, WARNING, switch, HA State out
of sync
2004/07/28-17:04:51, [EM-1055], 3,, WARNING, switch, Media 27: Port
media incompatible. Reason: Configured port speed.
2004/07/28-17:04:54, [FABR-1001], 4,, WARNING, switch, port 4, ELP
rejected by the other switch
2004/07/28-17:05:06, [FW-1050], 5,, WARNING, switch, Sfp Supply
Voltage 0, is below low boundary(High=3600, Low=3150). Current value
is 0 mV.
switch:admin>