HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

Fabric OS 5.x diagnostics and system error messages reference guide 395
TS Error Messages
TS-1001
Message
Probable Cause
Indicates that a network time protocol (NTP) query to the configured external clock server failed. Local
clock time on the principal or primary FCS switch is used for fabric synchronization.
This might be logged during temporary operational issues such as IP network connection issues to the
external clock server. If it does not recur, it can be ignored.
Recommended Action
Verify that the configured external clock server is available and functional. If that external clock server is
not available, choose another.
Severity
WARNING
TS-1002
Message
Probable Cause
Indicates that the fabric time synchronization distributed from the principal or primary FCS switch was not
sourced from the Type of clock server configured, instead, an alternate server was used, indicated by Type
of clock server used. The type of clock server used or configured might be either:
LOCL
Local clock on the principal or primary FCS switch
External
External NTP server address configured
This might be logged during temporary operational issues such as IP network connection issues to the
external clock server or if the fabric is configured for external time synchronization but the principal or
primary FCS does not support the feature. If the message does not recur, it should be ignored.
Recommended Action
Run the tsClockServer command to verify that the principal or primary FCS switch has the clock server IP
configured correctly. Verify that this clock server is accessible to the switch and functional. If the principal
oprimary FCS does not support the feature, either choose a different switch for the role or reset the clock
server to LOCL.
Severity
WARNING
<timestamp>, [TS-1001], <sequence-number>,, WARNING, <system-name>,
NTP Query failed: <error code>
<timestamp>, [TS-1002], <sequence-number>,, WARNING, <system-name>,
< Type of clock server used > Clock Server used instead of < Type of
clock server configured >: locl: 0x<code> remote: 0x<code>