392 Error messages
Probable Cause
Indicates that the standby CP is unable to communicate trace information to active CP. This message is only
applicable to the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director.
Recommended Action
Run the haShow command to verify that the current CP is standby and the active CP is active.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command on both CPs and contact your switch service provider.
Severity
ERROR
TRCE-1010
Message
Probable Cause
Indicates that the trace daemon (traced), used for transferring trace files, failed to start. The trace capability
within the switch is unaffected.
Recommended Action
Run traceFtp to set up for automatic FTP transfers.
Reboot the CP (dual-CP system) or restart the switch.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
ERROR
TRCE-1011
Message
Probable Cause
Indicates that a manual transfer of trace dump files has occurred.
Recommended Action
No action is required.
Severity
INFO
<timestamp>, [TRCE-1010], <sequence-number>,, ERROR, <system-name>,
Traced fails to start
<timestamp>, [TRCE-1011], <sequence-number>,, INFO, <system-name>,
Trace dump manually transferred to target ' <optional string to
indicate which slot the dump is ftped out.> ': <result>.