HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

388 Error messages
Severity
INFO
SYSM-1003
Message
Probable Cause
Indicates that the user executed the switchStart or switchReboot command. This indicates that all
services are brought back up after a temporary shutdown of that logical switch.
Recommended Action
No action is required if the switchStart command was executed intentionally. Because reinitializing a
switch is a disruptive operation and can stop I/O traffic, you might have to stop and restart the traffic
during this process.
Severity
INFO
SYSM-1004
Message
Probable Cause
Indicates that there was a failure to read configuration data from the WWN card.
Recommended Action
Verify that the WWN card is present and operational and that the affected CP is properly seated in its slot.
Severity
ERROR
TRCE Error Messages
TRCE-1001
Message
Probable Cause
Indicates that trace dump files have been generated on the switch or the indicated slot. The reason field
indicates the cause for generating the dump:
<timestamp>, [SYSM-1003], <sequence-number>,, INFO, <system-name>,
<number>, Switch: <start reason>
<timestamp>, [SYSM-1004], <sequence-number>,, ERROR, <system-name>,
Failed to retrieve current chassis configuration option,
ret=<Unknown>
<timestamp>, [TRCE-1001], <sequence-number>,, WARNING,
<system-name>, Trace dump available< optional slot indicating on
which slot the dump occurs >! (reason: <Text explanation of what
triggered the dump. (PANIC DUMP, WATCHDOG EXPIRED, MANUAL,
TRIGGER)>)