HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
386 Error messages
SYSC Error Messages
SYSC-1001
Message
Probable Cause
Indicates that during the boot sequence, one of the programs would not run on the system.
Recommended Action
If the message is reported during a reboot after new firmware has been loaded, try reloading the firmware
using the firmwareDownload command.
If the message persists, there might be a conflict between the two versions of firmware or the nonvolatile
storage might be corrupted.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
CRITICAL
SYSC-1002
Message
Probable Cause
Indicates that the system timed out during a reboot or failover sequence, waiting for one or more programs
to register with system services or to fail over to active status.
Recommended Action
The switch is in an inconsistent state and can be corrected only by a reboot or power cycle. Before
rebooting the chassis, record the firmware version on the switch (or CP) and run the haDump command.
If this is a dual-CP switch, then gather the output from the CP in which this log message appeared.
Severity
CRITICAL
SYSC-1003
Message
<timestamp>, [SYSC-1001], <sequence-number>,, CRITICAL,
<system-name>, Failed to run <Name of program that could not be run
(string)>:<System internal error message (string)>
<timestamp>, [SYSC-1002], <sequence-number>,, CRITICAL,
<system-name>, Switch bring-up timed out
<timestamp>, [SYSC-1003], <sequence-number>,, CRITICAL,
<system-name>, Chassis config option <Option number read from the
chassis option storage device> is not supported by CP blade with ID
<Blade ID (platform) number from Active CP>. Change the chassis
configuration.