HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

Fabric OS 5.x diagnostics and system error messages reference guide 385
Probable Cause
Indicates that the slot state has been detected as inconsistent during failover or recovery.
Recommended Action
On a Core Switch 2/64, SAN Director 2/128, or 4/256 SAN Director switch, run the slotPowerOff
and then the slotPowerOn command.
On a 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32, or
SAN Switch 4/32 switch, reboot or power cycle the switch.
Severity
ERROR
SWCH-1004
Message
Probable Cause
Indicates that a blade has failed during failover or recovery.
Recommended Action
On a Core Switch 2/64, SAN Director 2/128, or 4/256 SAN Director switch, run the slotPowerOff
and then the slotPowerOn command.
On a 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32, or
SAN Switch 4/32 switch, reboot or power cycle the switch.
Severity
ERROR
SWCH-1005
Message
Probable Cause
Indicates that the Diag blade attach has failed during failover or recovery.
Recommended Action
On a Core Switch 2/64, SAN Director 2/128, or 4/256 SAN Director switch, run the slotPowerOff
and then the slotPowerOn command.
On a 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32, or
SAN Switch 4/32 switch, reboot or power cycle the switch.
Severity
ERROR
<timestamp>, [SWCH-1004], <sequence-number>,, ERROR, <system-name>,
Blade attach failed during recovery, disabling slot = <slot number>
<timestamp>, [SWCH-1005], <sequence-number>,, ERROR, <system-name>,
Diag attach failed during recovery, disabling slot = <slot number>