HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
Fabric OS 5.x diagnostics and system error messages reference guide 357
SEC-1183
Message
Probable Cause
Indicates that a security database conversion has failed because of an invalid value.
Recommended Action
Retry the command with a valid value.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
ERROR
SEC-1184
Message
Probable Cause
Indicates that the specified action is applied to the specified RADIUS server configuration. The possible
actions are ADD, REMOVE, CHANGE, and MOVE.
Recommended Action
No action is required.
Severity
INFO
SEC-1185
Message
Probable Cause
Indicates that the switch database was enabled or disabled as the secondary AAA when RADUIS is the
primary AAA mechanism.
Recommended Action
No action is required.
Severity
INFO
<timestamp>, [SEC-1183], <sequence-number>,, ERROR, <system-name>,
Policy to binary conversion error: Port <port number> is out range.
<timestamp>, [SEC-1184], <sequence-number>,, INFO, <system-name>,
Radius config change, action <action>, server ID <server>.
<timestamp>, [SEC-1185], <sequence-number>,, INFO, <system-name>,
<action> switch DB.