HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
348 Error messages
Probable Cause
Indicates one of the following has occurred:
• The names for the specified policies have changed.
• The passwords have changed for the specified accounts.
• The SNMP community strings have been changed.
Recommended Action
Verify that the security event was planned. If the security event was planned, no action is required. If the
security event was not planned, take appropriate action as defined by your enterprise security policy.
Severity
INFO
SEC-1146
Message
Probable Cause
Indicates that the PID format of the switch was changed either to extended-edge PID or from extended-edge
PID. If the DCC polices existed, all area ID values either increased or decreased by 16. The values wrap
around after 128. If a DCC policy contains an area of 127 before changing to extended-edge PID, then
the new area is 15, because of the wraparound.
Recommended Action
No action is required.
Severity
INFO
SEC-1153
Message
Probable Cause
Indicates that RCS is not supported.
Recommended Action
Run the rcsInfoShow command to view RCS capability on the fabric. RCS must be capable on all
switches in the fabric to be enabled. If all switches are capable, it is automatically enabled.
For any switch that does not support RCS, obtain the latest firmware version from your switch supplier, and
run the firmwareDownload command to upgrade the firmware.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
INFO
<timestamp>, [SEC-1146], <sequence-number>,, INFO, <system-name>,
PID changed: <State>.
<timestamp>, [SEC-1153], <sequence-number>,, INFO, <system-name>,
Error in RCA: RCS is not supported