HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

338 Error messages
Recommended Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
the ready state. If a switch is in the error state, the database might not be correctly updated for that specific
switch.
Severity
ERROR
SEC-1100
Message
Probable Cause
Indicates that there has been a corruption during the distribution of the security database. This can only
occur when the primary FCS is distributing the security database to the other switches in the fabric and
local validation finds that there is an error in the security database. This is a rare occurence.
Recommended Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
the ready state. If a switch is in the error state, the database might not be correctly updated for that specific
switch.
Severity
ERROR
SEC-1101
Message
Probable Cause
Indicates that the security enable failed on the fabric because one or more switches in the fabric are busy.
Recommended Action
Verify that the security event was planned. If the security event was planned, run the secFabricShow
command to verify that all switches in the fabric are in the ready state. When all switches are in the ready
state, retry the operation.
Severity
ERROR
SEC-1102
Message
<timestamp>, [SEC-1100], <sequence-number>,, ERROR, <system-name>,
FCS switch present. Command terminated.
<timestamp>, [SEC-1101], <sequence-number>,, ERROR, <system-name>,
Failed to enable security on all switches. Please retry later.
<timestamp>, [SEC-1102], <sequence-number>,, ERROR, <system-name>,
Fail to download <security data>.