HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
330 Error messages
Severity
ERROR
SEC-1076
Message
Probable Cause
Indicates that the NoNodeWWNZoning option has been changed. If the option is turned on, a zone
member can be added using node WWNs, but the member will not be able to communicate with others
nodes in the zone.
Recommended Action
Reenable the current zone configuration for the change to take effect.
Severity
ERROR
SEC-1077
Message
Probable Cause
Indicates that the policy could not be activated. Reasons can be no memory, switch busy, and so on.
Recommended Action
Run the secFabricShow command to verify that all switches in the fabric are in the ready state. Retry the
command when all switches are ready.
Severity
ERROR
SEC-1078
Message
Probable Cause
Indicates that there has been a corruption during the distribution of the security database. This can only
occur when the primary FCS is distributing the security database to the other switches in the fabric and
local validation finds that there is an error in the security database. This is a rare occurence.
Recommended Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
the ready state. If a switch is in the error state, the database might not be correctly updated for that specific
switch.
<timestamp>, [SEC-1076], <sequence-number>,, ERROR, <system-name>,
NoNodeWWNZoning option has been changed.
<timestamp>, [SEC-1077], <sequence-number>,, ERROR, <system-name>,
Failed to activate new policy set on all switches.
<timestamp>, [SEC-1078], <sequence-number>,, ERROR, <system-name>,
No new data to abort.