HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

Fabric OS 5.x diagnostics and system error messages reference guide 313
Severity
WARNING
SEC-1005
Message
Probable Cause
Indicates that the primary FCS received a data request from the specified domain. For example, if the
switch fails to update the database or is attacked (data injection), a message is generated to the primary
FCS to try to correct and resync with the rest of the switches in the fabric.
Recommended Action
Check the fabric status, using secFabricShow to verify that the fabric is not being attacked by
unauthorized users.
Severity
INFO
SEC-1006
Message
Probable Cause
Indicates that invalid data has been received for any statistic-related command for security
(secStatsShow or secStatsReset). The counter is updated automatically when a security violation
occurs. This message might also occur if the updating counter fails.
Recommended Action
If the message is the result of a user command, retry the statistic command.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
SEC-1007
Message
<timestamp>, [SEC-1005], <sequence-number>,, INFO, <system-name>,
Primary FCS receives data request from domain <Domain number>
<timestamp>, [SEC-1006], <sequence-number>,, WARNING,
<system-name>, Security statistics error: Failed to reset due to
invalid <data>.
<timestamp>, [SEC-1007], <sequence-number>,, INFO, <system-name>,
Security violation: Unauthorized host with IP address <IP address
of the violating host> tries to establish API connection.