HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

304 Error messages
Recommended Action
No action is required.
Severity
INFO
PSWP-1004
Message
Probable Cause
Indicates that the portSwap configuration contradicts the chassis configuration.
Recommended Action
Redefine the port swap configuration so that it matches the chassis configuration.
Severity
WA R NIN G
RCS Error Messages
RCS-1001
Message
Probable Cause
Indicates that the RCS feature has been disabled on the local switch because not all switches in the fabric
support RCS or the switch is in nonnative mode.
Recommended Action
Run the rcsInfoShow command to view RCS capability on the fabric. RCS is supported in Fabric OS
v2.6, v3.1 and greater, v4.1 and greater.
Run the firmwareDownload command to upgrade the firmware for any switches that do not support
RCS.
Severity
INFO
RCS-1002
Message
<timestamp>, [PSWP-1004], <sequence-number>,, WARNING,
<system-name>, Port Swap configuration does not match Chassis
configuration for switch <switch number>. Erasing port swap
tables...
<timestamp>, [RCS-1001], <sequence-number>,, INFO, <system-name>,
RCS has been disabled. Some switches in the fabric do not support
this feature
<timestamp>, [RCS-1002], <sequence-number>,, INFO, <system-name>,
RCS has been enabled.