HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

Fabric OS 5.x diagnostics and system error messages reference guide 301
Severity
INFO
PS Error Messages
PS-1000
Message
Probable Cause
Indicates that an unexpected software error has occurred in Advanced Performance Monitoring. The
Performance Monitor has failed to initialize.
Recommended Action
The CP should reboot (or fail over) automatically. If it does not, reboot or power cycle the switch to
reinitiate the firmware.
Severity
CRITICAL
PS-1001
Message
Probable Cause
Indicates that the PID format was changed.
Recommended Action
No action is required. Refer to the
HP StorageWorks Fabric OS 5.x administrator guide
for more information
about the PID format.
Severity
INFO
PS-1002
Message
Probable Cause
Indicates that an unexpected software error has occurred in Advanced Performance Monitoring. The
Performance Monitor tracing system has failed to initialize.
<timestamp>, [PS-1000], <sequence-number>,, CRITICAL,
<system-name>, Failed to initialize Advanced Performance
Monitoring.
<timestamp>, [PS-1001], <sequence-number>,, INFO, <system-name>,
Advanced Performance Monitoring configuration updated due to change
in PID format
<timestamp>, [PS-1002], <sequence-number>,, ERROR, <system-name>,
Failed to initialize the tracing system for Advanced Performance
Monitoring.