300 Error messages
Probable Cause
Indicates that the standby CP is being reset. This message is typically generated by a CP that is in the
process of becoming the active CP. Note that in certain circumstances a CP may experience a double reset
and reboot twice in a row. A CP can recover automatically even if it has rebooted twice.
Recommended Action
No action is required.
Severity
INFO
PORT Error Messages
PORT-1003
Message
Probable Cause
Indicates that the specified port is now disabled because the link on this port had multiple failures that
exceed an internally set threshold on the port. This problem is typically related to hardware.
Recommended Action
Check and replace (if necessary) the hardware attached to both ends of the specified port number,
including:
the media (SFPs)
the cable (fiber optic or copper ISL)
the attached devices
When finished checking the hardware, perform portEnable to reenable the port.
Severity
WARNING
PORT-1004
Message
Probable Cause
Indicates that the specified port could not be enabled because other ports in the same port group have
used up the buffers available for this port group. This most likely occurs because the other ports are
configured as long distance.
Recommended Action
To enable this port, reconfigure the other E_Ports in the port group so they are either not long distance
ports or not E_Ports. This will free up buffers and allow the port to be enabled.
<timestamp>, [PORT-1003], <sequence-number>,, WARNING,
<system-name>, Port <port number> Faulted because of many Link
Failures
<timestamp>, [PORT-1004], <sequence-number>,, INFO, <system-name>,
Port <port number> could not be enabled because it is disabled due
to long distance.