HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
280 Error messages
LOG Error Messages
LOG-1000
Message
Probable Cause
Indicates that the previous message repeated the number of times specified by the repeat count.
Recommended Action
No action is required.
Severity
INFO
LOG-1001
Message
Probable Cause
Indicates that a log message was dropped.
Recommended Action
Run the reboot command for nonbladed switches or the haFailover command on bladed switches.
Run the saveCore command to FTP core files to a server location. It is normal behavior if there are no
core files to transfer.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
CRITICAL
LOG-1002
Message
Probable Cause
Indicates that a message was not recorded by the error logging system. A trace dump file is created. The
message might still be visible through SNMP or other management tools.
Recommended Action
Run the reboot command for nonbladed switches or the haFailover command on bladed switches.
<timestamp>, [LOG-1000], <sequence-number>,, INFO, <system-name>,
Previous message repeated <repeat count> time(s)
<timestamp>, [LOG-1001], <sequence-number>,, CRITICAL,
<system-name>, A log message was dropped
<timestamp>, [LOG-1002], <sequence-number>,, CRITICAL,
<system-name>, A log message was dropped