HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

268 Error messages
Recommended Action
Run the tempShow command to check if the switch temperatures are too high. Refer to the hardware
reference manual for the temperature range of your switch.
Run the fanShow command to verify that the fans are faulty.
For the SAN Switch 2/32 and SAN Switch 4/32, replace the fan FRU.
For the 4/8 SAN Switch, SAN Switch 2/8V and SAN Switch 2/16V, the entire switch must be replaced,
because these switches do not have FRUs.
Severity
ERROR
HIL-1306
Message
Probable Cause
Indicates that three fan FRUs have failed. This message is often preceded by a low fan speed message.
Recommended Action
Run the tempShow command to check if the switch temperatures are too high. Refer to the hardware
reference manual for the temperature range of your switch.
Run the fanShow command to verify that the fans are faulty.
For the SAN Switch 2/32 and SAN Switch 4/32, replace the fan FRU.
For the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/8V and SAN Switch 2/16V, the entire switch
must be replaced, because these switches do not have FRUs.
Severity
ERROR
HIL-1307
Message
Probable Cause
Indicates that multiple fan FRUs have failed. This message is often preceded by a low fan speed message.
Recommended Action
Run the tempShow command to check if the switch temperatures are too high. Refer to the hardware
reference manual for the temperature range of your switch.
Run the fanShow command to verify that the fans are faulty.
For the SAN Switch 2/32 and SAN Switch 4/32, replace the fan FRU.
For the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/8V and SAN Switch 2/16V, the entire switch
must be replaced, because these switches do not have FRUs.
<timestamp>, [HIL-1306], <sequence-number>,, ERROR, <system-name>,
Three fans failed. Replace failed fan FRUs immediately.
<timestamp>, [HIL-1307], <sequence-number>,, ERROR, <system-name>,
Four or five fans failed. Replace failed fan FRUs immediately.