HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
264 Error messages
HIL-1204
Message
Probable Cause
Indicates that the specified fan speed (in RPM) has fallen below the minimum threshold. This message is
specific to nonbladed switches and is not applicable to the Core Switch 2/64, SAN Director 2/128, or
4/256 SAN Director.
Recommended Action
Run the tempShow command to verify that the switch temperatures are within operational range. Refer to
the hardware reference manual for the temperature range of your switch.
Run the fanShow command to monitor the speed of the fan generating this error.
For the SAN Switch 2/32 and SAN Switch 4/32, if the fan problem is causing temperature problems on
the switch, replace the fan FRU.
For the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/8V and SAN Switch 2/16V, if the fan
problem is causing temperature problems on the switch,the entire switch must be replaced, because these
switches do not have FRUs.
Severity
ERROR
HIL-1205
Message
Probable Cause
Indicates that the specified fan speed (in RPM) has risen above the maximum threshold. A high speed does
not necessarily mean that the fan is faulty.
Recommended Action
Run the tempShow command to verify that the switch temperatures are within operational range. Refer to
the hardware reference manual for the temperature range of your switch.
Run the fanShow command to monitor the speed of the fan generating this error.
For the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/8V, SAN Switch 2/16V, if the fan problem is
causing temperature problems on the switch, you must replace the entire switch.
For the SAN Switch 2/32 and SAN Switch 4/32, if the fan problem is causing temperature problems on
the switch, replace the fan FRU.
Severity
ERROR
<timestamp>, [HIL-1204], <sequence-number>,, ERROR, <system-name>,
Fan <fan number> faulted, speed (<measured speed> RPM) below
threshold.
<timestamp>, [HIL-1205], <sequence-number>,, ERROR, <system-name>,
Fan <fan number> sensor <sensor number>, speed (<measured speed>
RPM) above threshold.