HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
262 Error messages
Probable Cause
Indicates that the switch voltage is above threshold. This message is specific to nonbladed switches and is
not applicable to the Core Switch 2/64, SAN Director 2/128, or 4/256 SAN Director.
Recommended Action
For the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/8V and SAN Switch 2/16V, the entire switch
must be replaced, because these switches do not have FRUs.
For the SAN Switch 2/32 and SAN Switch 4/32, replace the motherboard FRU.
Severity
CRITICAL
HIL-1108
Message
Probable Cause
Indicates that the switch voltage is below threshold. This message is specific to nonbladed switches and is
not applicable to the Core Switch 2/64, SAN Director 2/128, or 4/256 SAN Director.
Recommended Action
For the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/8V and SAN Switch 2/16V, the entire switch
must be replaced, because these switches do not have FRUs.
For the SAN Switch 2/32 and SAN Switch 4/32, replace the motherboard FRU.
Severity
CRITICAL
HIL-1201
Message
Probable Cause
Indicates that the fan speed (in RPM) has risen above the maximum threshold. A high speed does not
necessarily mean that the fan is faulty.
Recommended Action
Run the tempShow command to verify that the switch temperatures are within operational range. Refer to
the hardware reference manual for the temperature range of your switch.
Make sure that the area is well ventilated and that the room temperature is within operational range of
your switch. Refer to the hardware reference manual for your switch for the operational temperature range.
Run the fanShow command to monitor the speed of the fan generating this error.
For the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/8V, SAN Switch 2/16V, if the fan problem
causes the switch to have temperature problems, you must replace the entire switch.
<timestamp>, [HIL-1108], <sequence-number>,, CRITICAL,
<system-name>, Switch faulted, <nominal voltage> (<measured
voltage>) below threshold. System preparing for reset.
<timestamp>, [HIL-1201], <sequence-number>,, WARNING,
<system-name>, Blower <blower number>, speed (<measured speed> RPM)
above threshold.