HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

Fabric OS 5.x diagnostics and system error messages reference guide 261
Try to reseat the fan FRU and power supply FRU and verify that they are seated properly.
If the problem persists, replace the fan FRU or the power supply FRU as necessary.
Severity
ERROR
HIL-1105
Message
Probable Cause
Indicates that the switch voltage is above threshold. This message is specific to nonbladed switches and is
not applicable to the Core Switch 2/64, SAN Director 2/128, or 4/256 SAN Director.
Recommended Action
For the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/8V and SAN Switch 2/16V, the entire switch
must be replaced, because these switches do not have FRUs.
For the SAN Switch 2/32 and SAN Switch 4/32, replace the motherboard FRU.
Severity
ERROR
HIL-1106
Message
Probable Cause
Indicates that the switch voltage is below threshold. This message is specific to nonbladed switches and is
not applicable to the Core Switch 2/64, SAN Director 2/128, or 4/256 SAN Director.
Recommended Action
For the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/8V and SAN Switch 2/16V, the entire switch
must be replaced, because these switches do not have FRUs.
For the SAN Switch 2/32 and SAN Switch 4/32, replace the motherboard FRU.
Severity
ERROR
HIL-1107
Message
<timestamp>, [HIL-1105], <sequence-number>,, ERROR, <system-name>,
Switch error, <nominal voltage> (<measured voltage>) above
threshold.
<timestamp>, [HIL-1106], <sequence-number>,, ERROR, <system-name>,
Switch error, <nominal voltage> (<measured voltage>) below
threshold.
<timestamp>, [HIL-1107], <sequence-number>,, CRITICAL,
<system-name>, Switch faulted, <nominal voltage> (<measured
voltage>) above threshold. System preparing for reset.