HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

260 Error messages
Severity
ERROR
HIL-1102
Message
Probable Cause
Indicates that the blade voltage is below threshold. This message is specific to the Core Switch 2/64, SAN
Director 2/128, or 4/256 SAN Director.
Recommended Action
Replace the faulty blade.
Severity
ERROR
HIL-1103
Message
Probable Cause
Indicates that the fan voltage is above threshold.
Recommended Action
Run the psShow command to verify the power supply status.
Try to reseat the fan FRU and power supply FRU and verify that they are seated properly.
If the problem persists, replace the fan FRU or the power supply FRU as necessary.
Severity
ERROR
HIL-1104
Message
Probable Cause
Indicates that the fan voltage is below threshold.
Recommended Action
Run the psShow command to verify the power supply status.
<timestamp>, [HIL-1102], <sequence-number>,, ERROR, <system-name>,
Slot <slot number> faulted, <nominal voltage> (<measured voltage>)
is below threshold.
<timestamp>, [HIL-1103], <sequence-number>,, ERROR, <system-name>,
Blower <blower number> faulted, <nominal voltage> (<measured
voltage>) is above threshold.
<timestamp>, [HIL-1104], <sequence-number>,, ERROR, <system-name>,
Blower <blower number> faulted, <nominal voltage> (<measured
voltage>) is below threshold.