HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

252 Error messages
Recommended Action
Replace the FRU with the faulty temperature sensor.
Severity
WARNING
FW-1431
Message
Probable Cause
Indicates that the switch status is not in a healthy state. This occurred because the number of faulty fans is
greater than or equal to the policy set by the switchStatusPolicySet command. A fan is faulty when
sensor value is not in the acceptable range or is faulty.
Recommended Action
Replace the faulty or deteriorating fan FRUs.
Severity
WARNING
FW-1432
Message
Probable Cause
Indicates that the switch status is not in a healthy state. This occurred because the number of faulty WWN
cards is greater than or equal to the policy set by the switchStatusPolicySet command.
Recommended Action
Replace the faulty WWN card.
Severity
WARNING
FW-1433
Message
Probable Cause
Indicates that the switch status is not in a healthy state. This occurred because the number of faulty CPs is
greater than or equal to the policy set by the switchStatusPolicySet command. The CPs are
non-redundant.
<timestamp>, [FW-1431], <sequence-number>,, WARNING, <system-name>,
Switch status change contributing factor Fan: <Number Bad> bad.
<timestamp>, [FW-1432], <sequence-number>,, WARNING, <system-name>,
Switch status change contributing factor WWN: <Number Bad> bad.
<timestamp>, [FW-1433], <sequence-number>,, WARNING, <system-name>,
Switch status change contributing factor CP: CP non-redundant.