HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

Fabric OS 5.x diagnostics and system error messages reference guide 251
Severity
WARNING
FW-1428
Message
Probable Cause
Indicates that the switch status is not in a healthy state. This occurred because the number of missing power
supplies is greater than or equal to the policy set by the switchStatusPolicySet command.
Recommended Action
Replace the missing power supply.
Severity
WARNING
FW-1429
Message
Probable Cause
Indicates that the switch status is not in a healthy state. This occurred because the power supplies are not in
the correct slots for redundancy.
Recommended Action
Rearrange the power supplies so that one is in an odd slot and other in an even slot to make them
redundant.
Severity
WARNING
FW-1430
Message
Probable Cause
Indicates that the switch status is not in a healthy state. This occurred because the number of faulty
temperature sensors is greater than or equal to the policy set by the switchStatusPolicySet command.
A temperature sensor is faulty when the sensor value is not in the acceptable range or is faulty.
<timestamp>, [FW-1428], <sequence-number>,, WARNING, <system-name>,
Switch status change contributing factor Power supply: <Number
Missing> absent.
<timestamp>, [FW-1429], <sequence-number>,, WARNING, <system-name>,
Switch status change contributing factor: Power supplies are not
redundant.
<timestamp>, [FW-1430], <sequence-number>,, WARNING, <system-name>,
Switch status change contributing factor Temperature sensor:
<Number Bad> bad.