HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

248 Error messages
primary FCS switch have been executed on a non-primary FCS switch. There are many commands that can
be executed only on the primary FCS switch as well as one security command that can be executed only
on a backup FCS switch. The counter increments every time someone issues one of these commands on a
switch where it is not allowed.
Recommended Action
No action is required.
Severity
INFO
FW-1400
Message
Probable Cause
Indicates that the flash usage percentage has changed. Flash increases and decreases slightly with normal
operation of the switch. Excessive permanent increases can lead to future problems.
Recommended Action
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.
Severity
INFO
FW-1401
Message
Probable Cause
Indicates that the flash usage percentage has fallen below the low boundary. Flash increases and
decreases slightly with normal operation of the switch. Excessive permanent increases can lead to future
problems.
Recommended Action
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.
Severity
INFO
<timestamp>, [FW-1400], <sequence-number>,, INFO, <system-name>,
<Label>, value has changed(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
<timestamp>, [FW-1401], <sequence-number>,, INFO, <system-name>,
<Label>, is below low boundary(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.