HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
232 Error messages
Recommended Action
Run the errShow command to determine the device WWN, switch WWN, and switch port. Responses to
security-class messages depend on user policies. Consult your security administrator for response strategies
and policies.
Severity
WARNING
FW-1339
Message
Probable Cause
Indicates that the number of DCC violations has changed from a value outside of the acceptable range to
a value within the acceptable range. DCC violations indicate that an unauthorized device tried to join the
fabric. The DCC_POLICY allows for the specification of rules for binding device ports (typically HBA ports)
to specific switch ports. DCC policies ensure that whenever a device performs an FLOGI request that the
WWN specified in the FLOGI is validated to be connected to the authorized port. Enforcement for private
loop devices not performing FLOGI is done through the name server.
Recommended Action
No action is required.
Severity
INFO
FW-1340
Message
Probable Cause
Indicates that the number of login violations has changed. Login violations indicate that a login failure has
been detected.
Recommended Action
Run the errShow command to determine the IP location of the login attempt. Responses to security-class
messages depend on user policies. Consult your security administrator for response strategies and policies.
Severity
INFO
<timestamp>, [FW-1339], <sequence-number>,, INFO, <system-name>,
<Label>, is between high and low boundaries(High=<High value>,
Low=<Low value>). Current value is <Value> <Unit>.
<timestamp>, [FW-1340], <sequence-number>,, INFO, <system-name>,
<Label>, value has changed(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.