HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

228 Error messages
Probable Cause
Indicates that the number of front panel violations has changed. Front panel violations indicate that an
unauthorized front panel request has been received. The FRONTPANEL_POLICY contains a list of switch
WWNs for which front panel access is enabled.
Recommended Action
Run the errShow command to determine the WWN of the device that sent the request. Responses to
security-class messages depend on user policies. Consult your security administrator for response strategies
and policies.
Severity
INFO
FW-1329
Message
Probable Cause
Indicates that the number of front panel violations has fallen below the low boundary. Front panel
violations indicate that an unauthorized front panel request has been received. The FRONTPANEL_POLICY
contains a list of switch WWNs for which front panel access is enabled.
Recommended Action
No action is required.
Severity
INFO
FW-1330
Message
Probable Cause
Indicates that the number of front panel violations has risen above the high boundary. Front panel
violations indicate that an unauthorized front panel request has been received. The FRONTPANEL_POLICY
contains a list of switch WWNs for which front panel access is enabled.
Recommended Action
Run the errShow command to determine the WWN of the device that sent the request. Responses to
security-class messages depend on user policies. Consult your security administrator for response strategies
and policies.
Severity
WARNING
<timestamp>, [FW-1329], <sequence-number>,, INFO, <system-name>,
<Label>, is below low boundary(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
<timestamp>, [FW-1330], <sequence-number>,, WARNING, <system-name>,
<Label>, is above high boundary(High=<High value>, Low=<Low
value>). Current value is <Value> <Unit>.