HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
224 Error messages
FW-1318
Message
Probable Cause
Indicates that the number of SES violations has risen above the high boundary. SES violations indicate that
an SCSI Enclosure Services (SES) request has been received from an unauthorized WWN. The
SES_POLICY contains a list of WWNs of device ports that are allowed to access the SES Server
functionality.
Recommended Action
Run the errShow command to determine the WWN of the device that sent the request. Responses to
security-class messages depend on user policies. Consult your security administrator for response strategies
and policies.
Severity
WARNING
FW-1319
Message
Probable Cause
Indicates that the number of SES violations has changed from a value outside of the acceptable range to a
value within the acceptable range. SES violations indicate that an SCSI Enclosure Services (SES) request
has been received from an unauthorized WWN. The SES_POLICY contains a list of WWNs of device
ports that are allowed to access the SES Server functionality.
Recommended Action
No action is required.
Severity
INFO
FW-1320
Message
Probable Cause
Indicates that the number of MS violations has changed. MS violations indicate that a Management Server
(MS) access request has been received from an unauthorized WWN. The MS_POLICY contains a list of
WWNs of device ports that are allowed to access the Management Server functionality.
<timestamp>, [FW-1318], <sequence-number>,, WARNING, <system-name>,
<Label>, is above high boundary(High=<High value>, Low=<Low
value>). Current value is <Value> <Unit>.
<timestamp>, [FW-1319], <sequence-number>,, INFO, <system-name>,
<Label>, is between high and low boundaries(High=<High value>,
Low=<Low value>). Current value is <Value> <Unit>.
<timestamp>, [FW-1320], <sequence-number>,, INFO, <system-name>,
<Label>, value has changed(High=<High value>, Low=<Low value>).