HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

198 Error messages
Probable Cause
Indicates that the number of signal losses that the port experiences has fallen below the low boundary. Loss
of signal generally indicates a physical problem.
Recommended Action
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation. A low number of signal loss errors means that the switch is functioning normally.
Severity
INFO
FW-1170
Message
Probable Cause
Indicates that the number of signal losses that the port experiences has risen above the high boundary.
Loss of signal generally indicates a physical problem.
Recommended Action
Check both ends of your cable connection. Verify that the cable is not faulty.
Severity
WARNING
FW-1171
Message
Probable Cause
Indicates that the number of signal losses that the port experiences has changed from a value outside of
the acceptable range to a value within the acceptable range. Loss of signal generally indicates a physical
problem.
Recommended Action
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation. Frequent loss of signal generally indicates a physical problem.
Check both ends of your cable connection. Verify that the cable and SFPs are not faulty.
Severity
INFO
<timestamp>, [FW-1170], <sequence-number>,, WARNING, <system-name>,
<Port Name>, <Label>, is above high boundary(High=<High value>,
Low=<Low value>). Current value is <Value> <Unit>.
<timestamp>, [FW-1171], <sequence-number>,, INFO, <system-name>,
<Port Name>, <Label>, is between high and low boundaries(High=<High
value>, Low=<Low value>). Current value is <Value> <Unit>.