HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
182 Error messages
Probable Cause
Indicates that the value of the SFP voltage has changed.
Recommended Action
Frequent voltage fluctuations are an indication that the SFP is deteriorating. Replace the SFP.
Severity
INFO
FW-1050
Message
Probable Cause
Indicates that the value of the SFP voltage has fallen below the low boundary.
Recommended Action
Configure the low threshold to 1 so that the threshold triggers an alarm when the value falls to 0
(Out_of_Range). If continuous or repeated alarms occur, replace the SFP before it deteriorates.
Severity
WARNING
FW-1051
Message
Probable Cause
Indicates that the value of the SFP voltage has risen above the high boundary. High voltages indicate
possible hardware failures.
Recommended Action
Frequent voltage fluctuations are an indication that the SFP is deteriorating. Replace the SFP.
Severity
WARNING
FW-1052
Message
<timestamp>, [FW-1050], <sequence-number>,, WARNING, <system-name>,
<Label>, is below low boundary(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
<timestamp>, [FW-1051], <sequence-number>,, WARNING, <system-name>,
<Label>, is above high boundary(High=<High value>, Low=<Low
value>). Current value is <Value> <Unit>.
<timestamp>, [FW-1052], <sequence-number>,, INFO, <system-name>,
<Label>, is between high and low boundaries(High=<High value>,
Low=<Low value>). Current value is <Value> <Unit>.