HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
Fabric OS 5.x diagnostics and system error messages reference guide 175
If the power supply is functioning below the acceptable boundary, verify that it is seated correctly in the
chassis. Run the psShow command to view the status of the power supply. If the power supply continues
to be a problem, replace the faulty power supply.
Severity
INFO
FW-1010
Message
Probable Cause
Indicates that the power supply is faulty. The power supply is not producing enough power.
Recommended Action
Verify that you have installed the power supply correctly and that it is correctly seated in the chassis. If the
problem persists, replace the faulty power supply.
Severity
WARNING
FW-1011
Message
Probable Cause
Indicates that the power supply is functioning properly.
Recommended Action
No action is required. Set the high boundary above the normal operation range.
Severity
INFO
FW-1012
Message
Probable Cause
Indicates that the power supply counter changed from a value outside of the acceptable range to a value
within the acceptable range.
<timestamp>, [FW-1010], <sequence-number>,, WARNING, <system-name>,
<Label>, is below low boundary(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
<timestamp>, [FW-1011], <sequence-number>,, INFO, <system-name>,
<Label>, is above high boundary(High=<High value>, Low=<Low
value>). Current value is <Value> <Unit>.
<timestamp>, [FW-1012], <sequence-number>,, INFO, <system-name>,
<Label>, is between high and low boundaries(High=<High value>,
Low=<Low value>). Current value is <Value> <Unit>.