HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

174 Error messages
Severity
WARNING
FW-1007
Message
Probable Cause
Indicates that the speed of the fan has risen above the high boundary. Fan problems typically contribute to
temperature problems.
Recommended Action
Consistently abnormal fan speeds generally indicate that the fan is failing. Replace the fan FRU.
Severity
WARNING
FW-1008
Message
Probable Cause
Indicates that the speed of the fan has changed from a value outside of the acceptable range to a value
within the acceptable range. Fan problems typically contribute to temperature problems.
Recommended Action
No action is required. Consistently abnormal fan speeds generally indicate that the fan is failing. If this
message occurs repeatedly, replace the fan FRU.
Severity
INFO
FW-1009
Message
Probable Cause
Indicates that the state of the power supply has changed from faulty to functional or from functional to
faulty.
Recommended Action
If the power supply is functioning correctly, no action is required.
<timestamp>, [FW-1007], <sequence-number>,, WARNING, <system-name>,
<Label>, is above high boundary(High=<High value>, Low=<Low
value>). Current value is <Value> <Unit>.
<timestamp>, [FW-1008], <sequence-number>,, INFO, <system-name>,
<Label>, is between high and low boundaries(High=<High value>,
Low=<Low value>). Current value is <Value> <Unit>.
<timestamp>, [FW-1009], <sequence-number>,, INFO, <system-name>,
<Label>, value has changed(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.