HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
Fabric OS 5.x diagnostics and system error messages reference guide 157
Probable Cause
Indicates that the response frame received on the specified port for a inquiry request contains an invalid
value in the routing control field.
Recommended Action
This can happen only if the firmware on the device controller on the specified port has a defect. Check with
the device vendor for a firmware upgrade containing a defect fix.
Severity
WARNING
FCPD-1003
Message
Probable Cause
Private devices will not respond to the switch PLOGI during probing.
Recommended Action
Refer to the switch vendor for a list of other port types that support private devices for inclusion into the
fabric.
Severity
INFO
FCPH error messages
FCPH-1001
Message
Probable Cause
Indicates that the switch is low on memory and failed to allocate new memory for a Fibre Channel driver
instance.
The function can only be fc_create. This function creates a Fibre Channel driver instance.
The failed function call is kmalloc_wrapper failed. This function call is for kernel memory allocation.
Recommended Action
A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will automatically
fail over, and the standby CP will become the active CP.
Severity
CRITICAL
<timestamp>, [FCPD-1003], <sequence-number>,, INFO, <system-name>,
Probing failed on <error string> which is possibly a private device
which is not supported in this port type
<timestamp>, [FCPH-1001], <sequence-number>,, CRITICAL,
<system-name>, <function>: <failed function call> failed, out of
memory condition