HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

156 Error messages
FCMC error messages
FCMC-1001
Message
Probable Cause
Indicates that the switch is low on memory and failed to allocate new memory for an information unit (IU).
Recommended Action
A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will automatically
fail over and the standby CP will become the active CP.
Severity
CRITICAL
FCPD error messages
FCPD-1001
Message
Probable Cause
Indicates that an FCP switch probed devices on a loop port, and probing failed on the either the L_Port,
AL_PA address, or the F_Port. For the AL_PA, the valid range is 00 through FF. The error sting can be
either:
L_Port port_number ALPA alpa_number
F_Port port_number
Recommended Action
This can happen when the firmware on the device controller on the specified port has a defect. Check with
the device vendor for a firmware upgrade containing a defect fix.
The SAN Switch 4/32 does not support private loop devices.
Severity
WARNING
FCPD-1002
Message
<timestamp>, [FCMC-1001], <sequence-number>,, CRITICAL,
<system-name>, <function>: <failed function call> failed, out of
memory condition
<timestamp>, [FCPD-1001], <sequence-number>,, WARNING,
<system-name>, Probing failed on <error string>
<timestamp>, [FCPD-1002], <sequence-number>,, WARNING,
<system-name>, port <port number>, bad R_CTL for fcp probing:
0x<R_CTL value>