HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

154 Error messages
FABS-1011
Message
Probable Cause
An unrecognized state code was used in an internal Fabric OS message for a FRU.
Recommended Action
Reboot or power-cycle the CP or system.
If the message persists, run the firmwareDownload command to update the firmware.
Severity
ERROR
FABS-1012
Message
Probable Cause
A FRU could not be transitioned to the requested state. This is usually an internal Fabric OS problem.
Recommended Action
Reboot or power-cycle the CP or system.
If the message persists, run the firmwareDownload command to update the firmware.
Severity
ERROR
FABS-1013
Message
Probable Cause
An unrecognized type of blade has been discovered in the system.
This may be caused by an incorrect FRU header, inability to read the FRU header, or the blade may not be
supported by this platform or Fabric OS version.
Recommended Action
Verify that the blade is valid for use in this system and this version of Fabric OS
<timestamp>, [FABS-1011], <sequence-number>,, ERROR, <system-name>,
<Method name>[<Method tag number>]:Invalid input state 0x<Input
state code>
<timestamp>, [FABS-1012], <sequence-number>,, ERROR, <system-name>,
<Method name>[<Method tag number>]:FRU state transition failed.
Current state 0x<Current state of FRU> Requested state 0x<Requested
new state of FRU> err 0x<Error code>
<timestamp>, [FABS-1013], <sequence-number>,, ERROR, <system-name>,
<Method name>[<Method tag number>]:Unknown blade type 0x<Blade
type>