HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
Fabric OS 5.x diagnostics and system error messages reference guide 147
Probable Cause
Indicates that a failure occurred when trying to set the principal switch using the fabricPrincipal
command. The message notifies the user that the switch failed to become the principal switch because
either:
• The switch joined an existing fabric and bypassed the F0 state.
• The fabric already contains a principal switch that has a lower WWN.
Recommended Action
Make sure that no other switches is configured as the principal switch. Force a fabric rebuild by using the
switchDisable and switchEnable commands.
Refer to the
HP StorageWorks Fabric OS 5.x command reference guide
for more information the
fabricPrincipal command.
Severity
WARNING
FABR-1019
Message
Probable Cause
Indicates that this switch is a value-line switch and has exceeded the limited fabric size: that is, a specified
limit to the number of domains. This limit is defined by your specific value-line license key. The fabric size
has exceeded this specified limit, and the grace period counter has started. If the grace period is complete
and the size of the fabric is still outside the specified limit, Web Tools is disabled.
Recommended Action
Bring the fabric size within the licensed limits. Either a full fabric license must be added or the size of the
fabric must be changed to within the licensed limit. Contact your switch provider to obtain a full fabric
license.
Severity
CRITICAL
FABR-1020
Message
Probable Cause
Indicates that this switch has a value-line license and has a limited number of domains. If more than the
specified number of domains are in the fabric, a counter is started to disable Web Tools. This message
displays the number of days left in the grace period. After this time, Web Tools is disabled.
<timestamp>, [FABR-1019], <sequence-number>,, CRITICAL,
<system-name>, Critical fabric size (<current domains>) exceeds
supported configuration (<supported domains>)
<timestamp>, [FABR-1020], <sequence-number>,, CRITICAL,
<system-name>, Webtool will be disabled in <days> days <hours>
hours and <minutes> minutes