HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
136 Error messages
Severity
INFO
EM-1051
Message
Probable Cause
Indicates that an inconsistent state was found in the FRU. This occurs if the state of the FRU was changing
during a failover. The FRU is reinitialized and traffic might have been disrupted.
Recommended Action
No action is required.
Severity
INFO
EM-1052
Message
Probable Cause
Indicates that one or more sensor values for a FRU are radically out of range. This might be a
environmental problem or a problem with the sensor hardware.
The FRU ID value is composed of a FRU type string and an optional number to identify the unit, slot, or
port. The FRU ID value can be:
• Switch for fixed port count switches.
• Slot 1 through Slot 10 for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director.
• PS 1 through PS 4 (power supplies) for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN
Director, or PS 1 through PS 2 for the SAN Switch 2/32 and SAN Switch 4/32. The power supplies on
the SAN Switch 2/8V and the SAN Switch 2/16V are not field replaceable.
• Fan 1 through Fan 3 for the Core Switch 2/64, SAN Director 2/128, and SAN Switch 4/32 (six fans
in three FRUs). Fan 1 through Fan 6 for the SAN Switch 2/32 (six fans in three FRUs). The fans on the
SAN Switch 2/8V and the SAN Switch 2/16V are not field replaceable.
• WWN 1 or WWN 2 for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director. Only
bladed switches have removable WWN cards. All other switches have a non-removable WWN
component on the main logic board.
The SAN Switch 2/8V has one power supply and three fans, and the SAN Switch 2/16V has two power
supplies and four fans. Values for the individual fans and power supplies for these switches might display,
but these parts cannot be replaced: the entire switch is a FRU.
The does not have any fans, power supplies or WWN cards.
The 4/8 SAN Switch, 4/16 SAN Switch has 4 fans and 1 power supply, but these parts cannot be
replaced: the entire switch is a FRU. The 4/8 SAN Switch, 4/16 SAN Switch fans do not have RPM
sensors, so cannot display fan speed.
This message can display:
<timestamp>, [EM-1051], <sequence-number>,, INFO, <system-name>,
<FRU Id>: Inconsistency detected, FRU re-initialized
<timestamp>, [EM-1052], <sequence-number>,, WARNING, <system-name>, <FRU Id>
sensor 0x<Sensor Code> value out of range: <Raw Sensor Value>/<Retry Count>