HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
Fabric OS 5.x diagnostics and system error messages reference guide 133
been faulted, because it is indicating a predicted failure. If new_state is Down (not enough power), a
newly inserted port blade was not powered on because there was not enough power available.
Recommended Action
The Core Switch 2/64 requires two power supplies for a fully populated chassis; however, you should
always operate the system with four operating power supplies for redundancy.
The SAN Director 2/128 requires only a single power supply for a fully populated chassis; however, you
should always operate the system with at least two power supplies for redundancy.
Severity
WARNING
EM-1046
Message
Probable Cause
Indicates that the system controller encountered a blade with an unknown ID in the slot specified. This
message occurs only on the Core Switch 2/64 and SAN Director 2/128.
Recommended Action
The blade ID listed is not compatible with the chassisConfig option in effect. Use the chassisConfig
command to see a list of compatible blade ID’s for each option.
If the blade ID listed is not correct, then the FRU header for the blade is corrupted and the blade must be
replaced. For the Core Switch 2/64, the blade ID should be 1 for a CP blade and 2 for a port blade. For
the SAN Director 2/128, the blade ID should be 5 for a CP blade and 4 for a port blade. For the 4/256
SAN Director, the bladed ID should be 16 for a CP blade and 17 or 18 for a port blade.
Severity
WARNING
EM-1047
Message
Probable Cause
Indicates that the CP is no longer faulted. This message usually follows EM-1033. The new standby CP is in
the process of rebooting and has turned off the CP_ERR signal. This message occurs only on the Core
Switch 2/64, SAN Director 2/128, and 4/256 SAN Director.
Recommended Action
No action is required.
Severity
INFO
<timestamp>, [EM-1046], <sequence-number>,, WARNING, <system-name>, Sysctrl reports
error status for blade ID <id value> for the blade in slot <slot number>
<timestamp>, [EM-1047], <sequence-number>,, INFO, <system-name>, CP
in slot <slot number> not faulty, CP ERROR deasserted