HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

132 Error messages
The 4/8 SAN Switch, 4/16 SAN Switch has 4 fans and 1 power supply, but these parts cannot be
replaced: the entire switch is a FRU.
Recommended Action
Try reseating the FRU. If the message persists, replace the FRU.
Severity
WARNING
EM-1043
Message
Probable Cause
Indicates that the specified FRU cannot be powered on or off.
Recommended Action
The specified FRU is not responding to commands and should be replaced.
Severity
WARNING
EM-1044
Message
Probable Cause
Indicates that the specified FRU cannot be powered on because the associated logical switch is shut down.
This message only occurs on the Core Switch 2/64, and SAN Director 2/128.
Recommended Action
Run the switchStart command on the associated logical switch.
Severity
WARNING
EM-1045
Message
Probable Cause
Indicates that an automatic power adjustment is being made because of the (predicted) failure of a power
supply or the insertion or removal of a port blade. If new_state is On, a port blade is being powered on
because more power is available (either a power supply was inserted or a port blade was removed or
powered down). If new_state is Off, a port blade has been powered down because a power supply has
<timestamp>, [EM-1043], <sequence-number>,, WARNING, <system-name>,
Can't power <FRU Id> <state (on or off)>.
<timestamp>, [EM-1044], <sequence-number>,, WARNING, <system-name>,
Can't power on <FRU Id>, its logical switch is shut down
<timestamp>, [EM-1045], <sequence-number>,, WARNING, <system-name>, <FRU Id> is
being powered <new state>