HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
Fabric OS 5.x diagnostics and system error messages reference guide 129
Probable Cause
Indicates that the specified FRU has been marked as faulty for the specified reason.
The FRU ID value is composed of a FRU type string and an optional number to identify the unit, slot, or
port. The FRU ID value can be:
• Switch for fixed port count switches.
• Slot 1 through Slot 10 for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director.
• PS 1 through PS 4 (power supplies) for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN
Director, or PS 1 through PS 2 for the SAN Switch 2/32 and SAN Switch 4/32. The power supplies on
the SAN Switch 2/8V and the SAN Switch 2/16V are not field replaceable.
• Fan 1 through Fan 3 for the Core Switch 2/64, SAN Director 2/128, and SAN Switch 4/32 (six fans
in three FRUs). Fan 1 through Fan 6 for the SAN Switch 2/32 (six fans in three FRUs). The fans on the
SAN Switch 2/8V and the SAN Switch 2/16V are not field replaceable.
• WWN 1 or WWN 2 for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director. Only
bladed switches have removable WWN cards. All other switches have a non-removable WWN
component on the main logic board.
The SAN Switch 2/8V has one power supply and three fans, and the SAN Switch 2/16V has two power
supplies and four fans. Values for the individual fans and power supplies for these switches might display,
but these parts cannot be replaced: the entire switch is a FRU.
The does not have any fans, power supplies or WWN cards.
The 4/8 SAN Switch, 4/16 SAN Switch has 4 fans and 1 power supply, but these parts cannot be
replaced: the entire switch is a FRU.
Recommended Action
Try reseating the FRU.
Run the systemVerification command to verify that the switch does not have hardware problems. Refer
to the
HP StorageWorks Fabric OS 5.x command reference guide
for more information on this command.
If the message persists, replace the FRU.
Severity
ERROR
EM-1035
Message
Probable Cause
Indicates that both Power Supplies associated with one of the two main circuits are present but faulty, that
the circuits’s switch has been turned off, or the AC power source has been interrupted for that circuit.
The <switch side> value is either left or right designating which circuit switch, facing the cable side of the
chassis is possibly disabled. The switch side value indicates:
• left: controls the odd numbered power supply units.
• right: controls the even numbered power supply units.
This message only occurs on the Core Switch 2/64, SAN Director 2/128, or 4/256 SAN Director.
<timestamp>, [EM-1035], <sequence-number>,, ERROR, <system-name>, 2
circuit paired PS’s are faulty, please check the <switch side> AC
main switch/circuit to see if it has power.