HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
Fabric OS 5.x diagnostics and system error messages reference guide 123
Probable Cause
Indicates that a switch blade failed to transition from one state to another. It is faulted. The specific failed
target state is displayed in the message. There are serious internal Fabric OS configuration or hardware
problems on the switch.
The FRU ID value is composed of a FRU type string and an optional number to identify the unit, slot, or
port. The FRU ID value can be:
• Switch for fixed port count switches.
• Slot 1 through Slot 10 for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director.
Recommended Action
On Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director, try reseating the indicated FRU.
If the message persists, reboot or power cycle the switch.
Run the systemVerification command to verify that the switch does not have hardware problems. Refer
to the
HP StorageWorks Fabric OS 5.x command reference guide
for more information on this command.
If the message persists, replace the FRU.
Severity
CRITICAL
EM-1013
Message
Probable Cause
Indicates that the environmental monitor was unable to update the time alive or OEM data in the memory
on a FRU.
The FRU ID value is composed of a FRU type string and an optional number to identify the unit, slot, or
port. The FRU ID value can be:
• Switch for fixed port count switches.
• Slot 1 through Slot 10 for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director.
• PS 1 through PS 4 (power supplies) for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN
Director, or PS 1 through PS 2 for the SAN Switch 2/32 and SAN Switch 4/32. The power supplies on
the SAN Switch 2/8V and the SAN Switch 2/16V are not field replaceable.
• Fan 1 through Fan 3 for the Core Switch 2/64, SAN Director 2/128, 4/256 SAN Director, and SAN
Switch 4/32 (six fans in three FRUs). Fan 1 through Fan 6 for the SAN Switch 2/32 (six fans in three
FRUs). The fans on the SAN Switch 2/8V and the SAN Switch 2/16V are not field replaceable.
• WWN 1 or WWN 2 for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director. Only
bladed switches have removable WWN cards. All other switches have a non-removable WWN
component on the main logic board.
The SAN Switch 2/8V has one power supply and three fans, and the SAN Switch 2/16V has two power
supplies and four fans. Values for the individual fans and power supplies for these switches might display,
but these parts cannot be replaced: the entire switch is a FRU.
The does not have any fans, power supplies or WWN cards.
The 4/8 SAN Switch, 4/16 SAN Switch has 4 fans and 1 power supply, but these parts cannot be
replaced: the entire switch is a FRU.
<timestamp>, [EM-1013], <sequence-number>,, ERROR, <system-name>,
Failed to update FRU information for <FRU Id>