HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

Fabric OS 5.x diagnostics and system error messages reference guide 121
For the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/8V, and SAN Switch 2/16V you must
replace the switch.
Severity
CRITICAL
EM-1008
Message
Probable Cause
Indicates that a blade inserted in the specified slot is not compatible with the switch chassisConfig
option. The blade is faulted. This message occurs only on the Core Switch 2/64, SAN Director 2/128,
and 4/256 SAN Director.
Recommended Action
Replace the blade. Make sure the replacement blade is compatible with your CP type and
chassisConfig setting.
Severity
CRITICAL
EM-1009
Message
Probable Cause
Indicates that the environmental monitor (EM) received an unexpected power-down notification from the
specified FRU. This might indicate a hardware malfunction in the FRU. This message occurs only on the
Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director.
The FRU ID value is composed of a FRU type string and an optional number to identify the unit, slot, or
port. The FRU ID value can be:
Switch for fixed port count switches.
Slot 1 through Slot 10 for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director.
PS 1 through PS 4 (power supplies) for the Core Switch 2/64, SAN Director 2/128, and 4/256
SAN Director, or PS 1 through PS 2 for the SAN Switch 2/32 and SAN Switch 4/32. The power
supplies on the SAN Switch 2/8V and the SAN Switch 2/16V are not field replaceable.
Fan 1 through Fan 3 for the Core Switch 2/64, SAN Director 2/128, 4/256 SAN Director, and SAN
Switch 4/32 (six fans in three FRUs). Fan 1 through Fan 6 for the SAN Switch 2/32 (six fans in three
FRUs). The fans on the SAN Switch 2/8V and the SAN Switch 2/16V are not field replaceable.
WWN 1 or WWN 2 for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director. Only
bladed switches have removable WWN cards. All other switches have a non-removable WWN
component on the main logic board.
Recommended Action
<timestamp>, [EM-1008], <sequence-number>,, CRITICAL,
<system-name>, Unit in <FRU Id> faulted, incompatible with chassis
option <Chassis configuration option>
<timestamp>, [EM-1009], <sequence-number>,, CRITICAL,
<system-name>, <FRU Id> powered down unexpectedly