HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
Fabric OS 5.x diagnostics and system error messages reference guide 119
On the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director, replace the specified FRU.
For the SAN Switch 2/32, replace the motherboard FRU.
For the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/8V, SAN Switch 2/16V, and SAN Switch
4/32 you must replace the switch.
Severity
CRITICAL
EM-1004
Message
Probable Cause
Indicates that a FRU failed to power on and is not being used. The type of FRU is specified in the message.
The FRU ID value is composed of a FRU type string and an optional number to identify the unit, slot, or
port. The FRU ID value can be:
• Switch for fixed port count switches.
• Slot 1 through Slot 10 for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director.
• PS 1 through PS 4 (power supplies) for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN
Director, or PS 1 through PS 2 for the SAN Switch 2/32 and SAN Switch 4/32. The power supplies on
the SAN Switch 2/8V and the SAN Switch 2/16V are not field replaceable.
• Fan 1 through Fan 3 for the Core Switch 2/64, SAN Director 2/128, 4/256 SAN Director, and SAN
Switch 4/32 (six fans in three FRUs). Fan 1 through Fan 6 for the SAN Switch 2/32 (six fans in three
FRUs). The fans on the SAN Switch 2/8V and the SAN Switch 2/16V are not field replaceable.
• WWN 1 or WWN 2 for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director. Only
bladed switches have removable WWN cards. All other switches have a non-removable WWN
component on the main logic board.
The SAN Switch 2/8V has one power supply and three fans, and the SAN Switch 2/16V has two power
supplies and four fans. Values for the individual fans and power supplies for these switches might display,
but these parts cannot be replaced: the entire switch is a FRU.
The does not have any fans, power supplies or WWN cards.
The 4/8 SAN Switch, 4/16 SAN Switch has 4 fans and 1 power supply, but these parts cannot be
replaced: the entire switch is a FRU.
Recommended Action
Try reseating the FRU. If the message persists, replace the FRU.
Severity
CRITICAL
EM-1005
Message
<timestamp>, [EM-1004], <sequence-number>,, CRITICAL,
<system-name>, <FRU Id> failed to power on
<timestamp>, [EM-1005], <sequence-number>,, CRITICAL,
<system-name>, <FRU Id> has faulted. Sensor(s) above maximum limits