HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

Fabric OS 5.x diagnostics and system error messages reference guide 117
CONF error messages
CONF-1000
Message
Probable Cause
Indicates that the user with the switchadmin role does not have permission to update the Zoning and
Security configurations, so the Zoning and Security configurations are skipped while downloading the
configuration file.
Recommended Action
No action is required. You must login as admin to update the Zoning and Security configurations using the
configDownload command.
Severity
WARNING
EM error messages
EM-1001
Message
Probable Cause
Indicates that a field replaceable unit (FRU) is shutting down due to overheating. This is typically due to a
faulty fan but can also be caused by the switch environment.
Recommended Action
Verify that the location temperature is within the operational range of the switch. Refer to the hardware
reference manual for the environmental temperature range of your switch.
Run the fanShow command to verify that all fans are running at normal speeds. If any fans are missing
or are not performing at high enough speed, they should be replaced. Healthy fan speeds are as follows:
4/256 SAN Director fans run at approximately 2500 RPM.
SAN Director 2/128 fans run at approximately 2500 RPM.
Core Switch 2/64 fans run at approximately 2500 RPM.
SAN Switch 4/32 fans run at approximately 6000 RPM.
SAN Switch 2/32 fans run at approximately 3500 RPM.
SAN Switch 2/16V fans run at approximately 9000 RPM.
SAN Switch 2/8V fans run at approximately 5500 RPM.
4/8 SAN Switch, 4/16 SAN Switch has 4 fans. The 4/8 SAN Switch, 4/16 SAN Switch fans do not
have RPM sensors, so cannot display fan speed.
The SAN Switch 2/8V has three fans, and the SAN Switch 2/16V has four fans. Values for the individual
fans might display in this message, but these parts cannot be replaced: the entire switch is a FRU.
<timestamp>, [CONF-1000], <sequence-number>,, WARNING,
<system-name>, configDownload completed successfully but Zoning and
Security parts were ignored
<timestamp>, [EM-1001], <sequence-number>,, CRITICAL,
<system-name>, <FRU Id> is over heating: Shutting down