HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

116 Error messages
If the message persists, replace the blade.
Severity
CRITICAL
CDR error messages
CDR-1001
Message
Probable Cause
Indicates either a deteriorated SFP, an incompatible SFP pair, or a faulty cable between peer ports.
Recommended Action
Verify that you are using compatible SFPs on the peer ports.
Verify that the SFPs have not deteriorated and that the Fibre Channel cable is not faulty. Replace the SFPs
or cable if necessary.
Severity
WARNING
CER-1001 error messages
CER-1001
Message
Probable Cause
Indicates that the HA synchronization between the active and standby CPs is broken because there is
downlevel firmware loaded on the standby CP. The standby CP does not support the Advanced
Performance Tuning module when FICON Management Server is enabled.
Recommended Action
Run the firmwareDownload command to upgrade the firmware on the standby CP.
You can also disable FMS on the active CP.
Severity
ERROR
<timestamp>, [CDR-1001], <sequence-number>,, WARNING,
<system-name>, Port <port number> port fault. Please change the SFP
or check cable
<timestamp>, [CER-1001], <sequence-number>,, ERROR, <system-name>,
HA Sync broken, since standby Advanced Performance Tuning module
does not support FICON Management Server (FMS).