HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
Fabric OS 5.x diagnostics and system error messages reference guide 115
Recommended Action
No action is required.
Severity
INFO
BLL Error Messaages
BLL-1000
Message
Probable Cause
Indicates that a blade regulation problem was reported on the specified
slot number
. The blade is faulted.
This message occurs on only the Core Switch 2/64 and SAN Director 2/128.
The reason codes are as follows:
• 1 = Available buffer overflow
• 2 = Backend port buffer timeout
• 3 = Backend port got shut down
• 4 = Embedded port buffer timeout
• 5 = Excessive busy mini buffer
• 6 = Excessive RCC VC on E_Port
• 7 = Excessive RCC VC on FL_Port
• 8 = Fail detection buffer tag error
• 9 = Fail detection TX parity error
• 10 = EPI CMEM interrupt error
• 11 = CMI interrupt error
• 12 = Interrupt overrun
• 13 = FDET interrupt
• 14 = Interrupt suspended
• 15 = Filter LISTD error
• 16 = Unknown filter LIST error
• 17 = Wait for LPC open state
• 18 = Wait for Old port state
• 19 = Wait for Open init state
• 20 = TX parity error
• 21 = RAM parity error
• 22 = BISR or RAMINIT error
Recommended Action
Make sure that the blade is seated correctly.
If the blade is seated correctly, reboot or power cycle the blade.
Run the systemVerification command to verify that the blade does not have hardware problems. Refer
to the
HP StorageWorks Fabric OS 5.x command reference guide
for more information on this command.
<timestamp>, [BLL-1000], <sequence-number>,, CRITICAL,
<system-name>, ASIC driver detected Slot <slot number> port <port
number> as faulty (reason: <reason>)