HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

Fabric OS 5.x diagnostics and system error messages reference guide 115
Recommended Action
No action is required.
Severity
INFO
BLL Error Messaages
BLL-1000
Message
Probable Cause
Indicates that a blade regulation problem was reported on the specified
slot number
. The blade is faulted.
This message occurs on only the Core Switch 2/64 and SAN Director 2/128.
The reason codes are as follows:
1 = Available buffer overflow
2 = Backend port buffer timeout
3 = Backend port got shut down
4 = Embedded port buffer timeout
5 = Excessive busy mini buffer
6 = Excessive RCC VC on E_Port
7 = Excessive RCC VC on FL_Port
8 = Fail detection buffer tag error
9 = Fail detection TX parity error
10 = EPI CMEM interrupt error
11 = CMI interrupt error
12 = Interrupt overrun
13 = FDET interrupt
14 = Interrupt suspended
15 = Filter LISTD error
16 = Unknown filter LIST error
17 = Wait for LPC open state
18 = Wait for Old port state
19 = Wait for Open init state
20 = TX parity error
21 = RAM parity error
22 = BISR or RAMINIT error
Recommended Action
Make sure that the blade is seated correctly.
If the blade is seated correctly, reboot or power cycle the blade.
Run the systemVerification command to verify that the blade does not have hardware problems. Refer
to the
HP StorageWorks Fabric OS 5.x command reference guide
for more information on this command.
<timestamp>, [BLL-1000], <sequence-number>,, CRITICAL,
<system-name>, ASIC driver detected Slot <slot number> port <port