HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

114 Error messages
On the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/8V, SAN Switch 2/16V, or SAN Switch
4/32, replace the switch.
Severity
ERROR
BL-1016
Message
Probable Cause
Indicates that the specified blade port has failed to get enabled.
Recommended Action
Make sure that the blade is seated correctly.
If the blade is seated correctly, reboot or power cycle the blade.
Run the systemVerification command to verify that the blade does not have hardware problems. Refer
to the
HP StorageWorks Fabric OS 5.x command reference guide
for more information on this command.
If the message persists, replace the blade.
Severity
CRITICAL
BL-1017
Message
Probable Cause
Indicates that the slot has started initializing ports.
Recommended Action
No action is required.
Severity
INFO
BL-1018
Message
Probable Cause
Indicates that the slot has completed initializing the ports.
<timestamp>, [BL-1016], <sequence-number>,, CRITICAL,
<system-name>, Blade port <port number> in slot <slot number>
failed to enable.
<timestamp>, [BL-1017], <sequence-number>,, INFO, <system-name>,
Slot <port number> initializing...
<timestamp>, [BL-1018], <sequence-number>,, INFO, <system-name>,
Slot <port number> Initialization Completed