HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
Fabric OS 5.x diagnostics and system error messages reference guide 113
BL-1014
Message
Probable Cause
Indicates that the port generated an excessive number of interrupts that might prove fatal to the switch
operation. The port is disabled to prevent the CP from becoming too busy. The bport is the blade port; this
number might not correspond to a user port number.
Recommended Action
Make sure to capture the console output during this process.
On a bladed switch, run the slotPowerOff and slotPowerOn commands.
On a nonbladed switch, reboot the switch.
Run the systemVerification command to determine if there is a hardware error.
If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors
are encountered again:
• On the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director, replace the blade FRU.
• On the SAN Switch 2/32, replace the motherboard FRU.
• On the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/8V, SAN Switch 2/16V, or SAN Switch
4/32, replace the switch.
Severity
ERROR
BL-1015
Message
Probable Cause
Indicates that the port generated an excessive number of interrupts that might prove fatal to the switch
operation. The port is disabled to prevent the CP from becoming too busy. The bport is the blade port; this
number might not correspond to a user port number.
Recommended Action
Make sure to capture the console output during this process.
On a bladed switch, run the slotPowerOff and slotPowerOn commands.
On a nonbladed switch, reboot the switch.
Run the systemVerification command to determine if there is a hardware error.
If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors
are encountered again:
• On the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director, replace the blade FRU.
• On the SAN Switch 2/32, replace the motherboard FRU.
<timestamp>, [BL-1014], <sequence-number>,, ERROR, <system-name>,
bport <port number> port int. is disabled. status=0x<interrupt
status>
<timestamp>, [BL-1015], <sequence-number>,, ERROR, <system-name>,
bport <port number> port is faulted. status=0x<interrupt status>