HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

Fabric OS 5.x diagnostics and system error messages reference guide 111
Severity
CRITICAL
BL-1010
Message
Probable Cause
Indicates that a failover occurred while some hardware changes were being made on the previously active
CP (such as changing the domain ID). This message occurs on only the Core Switch 2/64, SAN Director
2/128, and 4/256 SAN Director.
Recommended Action
No action is required. This blade has been reinitialized. Because reinitializing a blade is a disruptive
operation and can stop I/O traffic, you might have to stop and restart the traffic during this process.
Severity
WARNING
BL-1011
Message
Probable Cause
Indicates that too many interrupts in the embedded port caused the specified chip to be disabled. The
probable cause is too many abnormal frames; the chip is disabled to prevent the CP from becoming too
busy.
Recommended Action
Make sure to capture the console output during this process.
Check for a faulty cable, SFP, or device attached to the specified port.
Run the systemVerification command to verify that the blade or switch does not have hardware
problems.
On a bladed switch, run the slotPowerOff and slotPowerOn commands.
On a nonbladed switch, reboot or power cycle the switch.
If the message persists, replace the blade or the (nonbladed) switch.
Severity
CRITICAL
<timestamp>, [BL-1010], <sequence-number>,, WARNING, <system-name>,
Blade in slot <slot number> inconsistent with the hardware
settings.
<timestamp>, [BL-1011], <sequence-number>,, CRITICAL,
<system-name>, Busy with emb-port int. for chip <chip number> in
minis <minis number> on blade <slot number>, chip int. is disabled.
interrupt status=0x<interrupt status>