HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
Fabric OS 5.x diagnostics and system error messages reference guide 109
Severity
CRITICAL
BL-1004
Message
Probable Cause
Indicates that the specified blade experienced a failure but was not faulted due to a user setting. This
message occurs on only the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director.
Recommended Action
Reboot or power cycle the blade, using the slotPowerOff and slotPowerOn commands.
Run the systemVerification command to verify that the blade does not have hardware problems. Refer
to the
HP StorageWorks Fabric OS 5.x command reference guide
for more information on this command.
If the message persists, replace the blade.
Severity
CRITICAL
BL-1006
Message
Probable Cause
Indicates that the errors (mostly synchronization errors) on this blade are harmless. Probably, the standby
CP blade connected to the active CP blade has experienced transitory problems. This message occurs only
on the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director.
Recommended Action
Verify that the standby CP is healthy. If the standby CP was removed or faulted by user intervention, no
action is required.
Severity
INFO
BL-1007
Message
<timestamp>, [BL-1004], <sequence-number>,, CRITICAL,
<system-name>, Suppressing blade fault in slot <slot number>
<timestamp>, [BL-1006], <sequence-number>,, INFO, <system-name>,
Blade <slot number> NOT faulted. Peer blade <slot number>
experienced abrupt failure.
<timestamp>, [BL-1007], <sequence-number>,, WARNING, <system-name>,
blade #<blade number>: blade state is inconsistent with EM.
bl_cflags 0x<blade control flags>, slot_on <slot_on flag>, slot_off
<slot_off flag>, faulty <faulty flag>, status <blade status>