HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
102 Error messages
AUTH-1025
Message
Probable Cause
Indicates the authentication process failed to get expected information during the specified authentication
phase.
Recommended Action
Usually this problem is transient. The authentication might fail.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable
and switchEnable commands.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
ERROR
AUTH-1027
Message
Probable Cause
Indicates that the authentication process failed to select an authentication value (that is, DH Group, hash
value, or protocol type) from a receiving payload for a particular authentication phase. This indicates that
the local switch does not support the specified authentication value.
Recommended Action
Check the authentication configuration and reset the supported value if needed using the authUtil
command.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable
and switchEnable commands.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
ERROR
<timestamp>, [AUTH-1025], <sequence-number>,, ERROR, <system-name>,
Failed to get <data type> during <authentication phase>: port <port
number>
<timestamp>, [AUTH-1027], <sequence-number>,, ERROR, <system-name>,
Failed to select <authentication value> during <authentication
phase>: value <value> port <port number>.