HP StorageWorks Fabric OS 5.X Command Reference Guide (AA-RVHVB-TE, September 2005)

Table Of Contents
692 Fabric OS commands
Port State Port state information
No_Card
No_Module
Mod_Val
No_Light
No_Sync
In_Sync
Laser_Flt
Port_Flt
Diag_Flt
Lock_Ref
Testing
Online
No interface card present.
No module (SFP or other) present.
Module validation in process.Mod_Inv – nvalid module.
Module not receiving light.
Module receiving light but out of sync.
Module receiving light and in sync.
Module signaling a laser fault.
Port marked faulty.
Port failed diagnostics.
Locking to the reference signal.
Running diagnostics.
Port is up and running.
comment The comment field is blank, or displays:
Disabled
Bypassed
Loopback
E_Port
F_Port
G_Port
L_Port
(Trunk master)
(upstream)
(downstream)
Port is disabled.
Port is bypassed (loop only).
Port is in loopback mode.
Fabric port; displays WWN and name of attached
switch.
Point-to-point port; displays WWN of attached N_Port.
Point-to-point but not yet E_Port or F_Port.
Loop port; displays number of NL_Ports.
Port is the master port in a group of trunking ports.
(Trunk port, master is port #x) – Port is configured as a
trunking port; the master port is port number x.
E_Port is an upstream path towards the principal switch
of the fabric.
E_Port is a downstream path away from the principal
switch of the fabric.
Persistently Disabled
This port has been disabled using
portCfgPersistentDisable.
FICON – Persistent DID
This port has been disabled since the switch could not
obtain its configuration domain ID during the fabric
reconfiguration when FICON mode was enabled. See
ficonShow for more information.
If a port is configured as a long distance port, the long
distance level is displayed in the format of Lx, which
represents the long distance level number. See
portCfgLongDistance for more information